Print Report | Back to Test Summary

Testing Report for 2020-04-02-2-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07296404
EFIS: 0713000031
Project ID: 212827
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5,10,60-16.1/17.0,18.1/18.4,0.4/R1.0
Work Description: PLACE ROCK BLANKET, MINOR CONCRETE, AND WEED CONTROL MAT.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES ON ROUTE 5 FROM EUCLID AVENUE UNDERCROSSING TO SEVENTH STREET OVERCROSSING AND ON ROUTE 10 FROM LA RIVER TO ROUTE 5 AND ON ROUTE 60 FROM SOTO STREET UNDERCROSSING TO EAST OF EUCLID AVENUE UNDERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Hassan Azima
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-04-02-2
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 4/2/2020
Date that the sample was received by the laboratory/organization performing the testing: 4/3/2020
The quantity of what the sample constitutes: 6 Bags
A brief description of the sample: 3/4 WMA-A-SP R15
From where was the sample collected: Manufacturer
Laboratory sample identification: 0183A-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Sun Valley

Material Information

Source Identification (SMARA or name of Pit): 91-19-0017, 91-19-0019, 91-19-0021
The fabricator's/manufacturer's product name for the sample: 3/4 WMA-A-SP R15
The fabricator/manufacturer designation for the sample: Unknown
The plant number: 22086 SVA SJR
A detailed description of where the material sample was collected: Belt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown

Test Information

DIME Test ID: 2020-04-02-2-3
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Date Tested: 4/7/2020
Verified Date: 5/7/2020
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test: RAP Gradation After Ignition Oven
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 89 %
Cumulative percent passing the 3/8 in. sieve: 93 %
Cumulative percent passing the #4 sieve: 73 %
Cumulative percent passing the #8 sieve: 55 %
Cumulative percent passing the #16 sieve: 43 %
Cumulative percent passing the #30 sieve: 32 %
Cumulative percent passing the #50 sieve: 22 %
Cumulative percent passing the #100 sieve: 14 %
Cumulative percent passing the #200 sieve: 9.6 %