Print Report | Back to Test Summary

Testing Report for 2019-09-18-17-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07202124
EFIS: 0700020870
Project ID: 212888
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-20.9/24.6
Work Description: PAVEMENT REHABILITATION AND BRIDGE WIDENING
Location Description: LOS ANGELES COUNTY IN AND NEAR BELL, VERNON, AND CITY OF COMMERCE, FROM 0.2 MILE SOUTH OF SLAUSON AVENUE OVERCROSSING TO 0.1 MILE NORTH OF THIRD STREET OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Peter Lee
Structure Rep.: James Holloway

Sample Information

DIME Sample ID: 2019-09-18-17
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 9/18/2019
Date that the sample was received by the laboratory/organization performing the testing: 10/2/2019
The quantity of what the sample constitutes: JMF 6 bags
A brief description of the sample: 1/2 HMA-A-SP R15
From where was the sample collected: Manufacturer
Laboratory sample identification: 0592A-19
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt Corona

Material Information

Source Identification (SMARA or name of Pit): 91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample: 1/2 HMA-A-SP R15
The fabricator/manufacturer designation for the sample: 104775
The plant number: Unknown
A detailed description of where the material sample was collected: Belt Cut at All American Irwindale Plant
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown

Test Information

DIME Test ID: 2019-09-18-17-9
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Date Tested: 10/7/2019
Verified Date: 5/7/2020
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test: RAP Gradation After Ignition Oven
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 99 %
Cumulative percent passing the 3/8 in. sieve: 95 %
Cumulative percent passing the #4 sieve: 76 %
Cumulative percent passing the #8 sieve: 58 %
Cumulative percent passing the #16 sieve: 44 %
Cumulative percent passing the #30 sieve: 32 %
Cumulative percent passing the #50 sieve: 22 %
Cumulative percent passing the #100 sieve: 14 %
Cumulative percent passing the #200 sieve: 10 %