Summary for Test 2020-12-01-2-4
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 213856 DEA: 112888U4 EFIS: 1118000199 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-11,125,905-Various |
| Award Date | 05/09/2019 |
| Closeout Date | 09/14/2023 |
| Work Description | CONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
| Sample Taken Date | 12/01/2020 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/02/2020 | Sample type | Quality Assurance |
| A brief description of the sample | No 11 Headed Reinforcement | The quantity of what the sample constitutes | 1 Lot of 74 Headed Bars |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Weeks | Title of sampler | ASI |
| Telephone number of sampler | 310-883-8369 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Integrity Rebar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-068-20 | |
| Structure unique identifier | Structure name | Alta Road Overcrossing | |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 65029069 | Head Manufacturer Lot Number(s) | A201362 |
| Rebar Size | #11 | Headed Bar Model Name | Buttonhead BNX |
| Size of Head | Full Size - 9x | Head Connection Type | Crimped Head |
| Head Shape | Circular | Rebar Manufacturer | Gerdau |
| Head Manufacturer | Bar Splice | Head Fabricator | Integrity Rebar |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2020-12-01-2
DIME Test ID: 2020-12-01-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-12-02
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 12/02/2020
UTM: 400kip
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 2 | 1.56 | 145303 | 93143 | Head Pull off | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Head Pull off
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 12/2/2020 ✔