Summary for Test 2020-09-20-12-1

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 215313
DEA: 044Q3200
EFIS: 0419000376
DIST-CO-RTE-PM04-MRN-37-11.2/13.7
Award Date03/31/2027
Closeout DateNot set
Work DescriptionMRN 37 SUSTAINABILITY LONG LEAD PROJECT
Location DescriptionNot set
QA Service Level1 (Verified on 11/09/2020)

Sample Information

Sample Taken Date09/20/2020 Sample Unique Key12
Date that the sample was received by the laboratory/organization performing the testing11/18/2020 Sample typePer Request
A brief description of the samplenative soil The quantity of what the sample constitutesbag of soil
From where was the sample collectedJob Site First name of sampler or witnessed byHunter
Last name of sampler or witnessed byRingrose Title of samplerTransportation Engineer
Telephone number of sampler510-286-4811 Laboratory sample identificationCR20200495
Linked DIME Sample ID The fabricator/manufacturer/facility nameCaltrans
Transportation Laboratory (TL) NumberCHR0014 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier04-SON-037, PM0.0-3.9 Structure nameWestbound SR37
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleSoil RW-20-005
The fabricator/manufacturer designation for the sampleFoundation investigation A detailed description of where the material sample was collected15-16.5 feet depth
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2020-09-20-12
DIME Test ID: 2020-09-20-12-1
Testing Lab: WSP USA - San Diego
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-12-01

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Michael Gibson
Date of test: 11/25/2020
Minimum soil resistance of the lab measurement: 54 Ohms
Soil sample temperature: 25.9 C
Soil box constant: 1
pH of soil: 6.00
Minimum soil resistance corrected to 15.5: 68 Ohm-cm
Minimum soil resistivity at 15.5: 68 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/1/2020 ✔