Summary for Test 2020-11-03-14-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 214830 DEA: 043G6304 EFIS: 0412000409 |
---|---|
DIST-CO-RTE-PM | 04-SCL-4-SCl-9 -4.75/4.9 |
Award Date | 11/08/2022 |
Closeout Date | Not set |
Work Description | Saratoga Creek Bridge Rehabilitation Project |
Location Description | San Jose - Saratoga Creek |
QA Service Level | 1 (Verified on 11/09/2020) |
Sample Information
Sample Taken Date | 11/03/2020 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/18/2020 |
Sample type | Per Request | A brief description of the sample | soil |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Justin | Last name of sampler or witnessed by | Anderson |
Title of sampler | Transportation Engineer | Telephone number of sampler | 925-989-0909 |
Laboratory sample identification | CR20200535 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | C002424 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 04-SCL-009-4.9 | |
Structure name | Sample 3 |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | RC-20-003 sample 3 |
---|---|---|---|
The fabricator/manufacturer designation for the sample | corrosion testing | A detailed description of where the material sample was collected | 15 feet depth |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-11-03-14
DIME Test ID: 2020-11-03-14-1
Testing Lab: WSP USA - San Diego
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-12-01
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Sarah Mauri
Date of test: 11/23/2020
Minimum soil resistance of the lab measurement: 3800 Ohms
Soil sample temperature: 20.8 C
Soil box constant: 1
pH of soil: 7.38
Minimum soil resistance corrected to 15.5: 4304 Ohm-cm
Minimum soil resistivity at 15.5: 4304 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/1/2020 ✔