Summary for Test 2020-10-14-37-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 215315 DEA: 081H8304 EFIS: 0817000139 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD,SBD-138-0/2.3 |
| Award Date | 11/19/2021 |
| Closeout Date | 08/29/2024 |
| Work Description | CONSTRUCT 4' MEDIAN |
| Location Description | SAN BERNARDINO COUNTY ALONG ROUTE 138 |
| QA Service Level | 1 (Verified on 06/24/2021) |
Sample Information
| Sample Taken Date | 10/14/2020 | Sample Unique Key | 37 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/18/2020 | Sample type | Per Request |
| A brief description of the sample | soil | The quantity of what the sample constitutes | 1 bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Kazi |
| Last name of sampler or witnessed by | Ahmed | Title of sampler | Unknown |
| Telephone number of sampler | 909-806-3964 | Laboratory sample identification | CR20200516 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Caltrans | |
| Transportation Laboratory (TL) Number | C002253 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | 08-SBD-138-PM 1.5 | Structure name | Southbound |
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | A-20-004 |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Soil Corrosion | A detailed description of where the material sample was collected | 5 feet depth |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-10-14-37
DIME Test ID: 2020-10-14-37-1
Testing Lab: WSP USA - San Diego
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-11-24
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Sarah Mauri
Date of test: 11/20/2020
Minimum soil resistance of the lab measurement: 3500 Ohms
Soil sample temperature: 20.5 C
Soil box constant: 1
pH of soil: 7.79
Minimum soil resistance corrected to 15.5: 3938 Ohm-cm
Minimum soil resistivity at 15.5: 3938 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/24/2020 ✔