Summary for Test 2020-10-16-11-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 215317 DEA: 101J0104 EFIS: 1018000079 |
|---|---|
| DIST-CO-RTE-PM | 10-CAL,CAL-88,34-34.6/2.2 |
| Award Date | 05/19/2022 |
| Closeout Date | 11/16/2023 |
| Work Description | Construct fuel island canopies. |
| Location Description | In Calaveras and Alpine counties on Route 26 at the West Point Maintenance Station and on Route 88 at the Caples Lake Maintenance Station. |
| QA Service Level | 1 (Verified on 07/29/2022) |
Sample Information
| Sample Taken Date | 10/16/2020 | Sample Unique Key | 11 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/18/2020 | Sample type | Per Request |
| A brief description of the sample | top soil for corrosion testing | The quantity of what the sample constitutes | bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Keith |
| Last name of sampler or witnessed by | M | Title of sampler | Geologist |
| Telephone number of sampler | 916-719-4791 | Laboratory sample identification | CR20200503 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Caltrans | |
| Transportation Laboratory (TL) Number | C529044 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | 10-ALP-88-0/0 | Structure name | Woodfords MS |
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Top Soil sample |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | corrosion | A detailed description of where the material sample was collected | 1-5 feet depth |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-10-16-11
DIME Test ID: 2020-10-16-11-1
Testing Lab: WSP USA - San Diego
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-11-24
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Sarah Mauri
Date of test: 11/20/2020
Minimum soil resistance of the lab measurement: 4500 Ohms
Soil sample temperature: 20.4 C
Soil box constant: 1
pH of soil: 6.25
Minimum soil resistance corrected to 15.5: 5051 Ohm-cm
Minimum soil resistivity at 15.5: 5051 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/24/2020 ✔