Summary for Test 2020-10-01-18-2
Test performed: ASTM D36-14ε1Project Information
| Project Identifiers | Project ID: 213485 DEA: 032F9804 EFIS: 0312000026 |
|---|---|
| DIST-CO-RTE-PM | 03-COL-20-31.7/32.9 |
| Award Date | 10/15/2018 |
| Closeout Date | 05/11/2022 |
| Work Description | PAVEMENT REHABILITATION |
| Location Description | COLUSA COUNTY IN AND NEAR COLUSA FROM 0.1 MILE EAST OF THE MARKET STREET/STATE ROUTE 20 INTERSECTION TO 0.1 MILE SOUTH OF BUTTE VISTA DRIVE |
| QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
| Sample Taken Date | 10/01/2020 | Sample Unique Key | 18 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/06/2020 | Sample type | Department Acceptance |
| A brief description of the sample | #1 Test, No Test #2(779010),#3(779003) | The quantity of what the sample constitutes | 2 cans each |
| From where was the sample collected | Source | First name of sampler or witnessed by | Brad |
| Last name of sampler or witnessed by | McKeehan | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | FNF | |
| Transportation Laboratory (TL) Number | 779004 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-01-18
DIME Test ID: 2020-10-01-18-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2020-11-20
Test Results
ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 11/20/2020
Softening Point Sample 1: 68 C
Softening Point Sample 2: 68 C
Bath Liquid: USP glycerin
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 11/20/2020 ✔