Summary for Test 2020-10-27-10-3
Test performed: ASTM D5329-16Project Information
| Project Identifiers | Project ID: 213525 DEA: 010A0404 EFIS: 0100020013 |
|---|---|
| DIST-CO-RTE-PM | 01-LAK-175-R25.0/27.5 |
| Award Date | 10/15/2018 |
| Closeout Date | 11/02/2021 |
| Work Description | Putah Creek Bridge Widen +1 + 2RCBs |
| Location Description | LAKE COUNTY AT AND NEAR MIDDLETOWN FROM 0.1 MILE EAST OF PUTAH CREEK BRIDGE TO DRY CREEK BRIDGE |
| QA Service Level | 1 (Verified on 08/24/2018) |
Sample Information
| Sample Taken Date | 10/27/2020 | Sample Unique Key | 10 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/04/2020 | Sample type | Department Acceptance |
| A brief description of the sample | RHMA #1 test | The quantity of what the sample constitutes | 1 can |
| From where was the sample collected | Source | First name of sampler or witnessed by | jerry |
| Last name of sampler or witnessed by | Oliver | Title of sampler | Consultant |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | BoDean Company Santa Rosa | |
| Transportation Laboratory (TL) Number | 827405 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | 1 |
| Sublot number | 1 | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-27-10
DIME Test ID: 2020-10-27-10-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2020-11-20
Test Results
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 11/20/2020
Temperature: 25 C
Ball Penetration (P1): 0 mm
Final Dial reading (F1): 76 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F2): 74 mm
Ball Penetration (P3): 0 mm
Final Dial reading (F3): 74 mm
Resilience 1: 24 %
Resilience 2: 26 %
Resilience 3: 26 %
Average Resilience: 25 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 11/20/2020 ✔