Summary for Test 2020-04-17-18-6

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 214628
DEA: 031G6604
EFIS: 0319000116
DIST-CO-RTE-PM03-BUT-162-12.6/15.6
Award Date03/17/2020
Closeout Date07/09/2021
Work DescriptionCOLD IN-PLACE RECYCLING, RHMA-G OVERLAY, AND COLD PLANE AC PAVEMENT.
Location DescriptionBUTTE COUNTY IN AND NEAR OROVILLE FROM 0.8 MILE EAST OF WILBUR ROAD TO FEATHER RIVER BRIDGE
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date04/17/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/20/2020
Sample typeVerification A brief description of the sample1/2 inch RHMA-G
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byKenny witness not sampler Last name of sampler or witnessed byMcHugh witness not sampler
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert-Hallwood Drum Plant Transportation Laboratory (TL) NumberC779100
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-04-17-18
DIME Test ID: 2020-04-17-18-6
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2020-11-13

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 06/02/2020
Wet 1Wet 2Wet 3Dry 1Dry 2Dry 3
Untreated

121 psi

144 psi

84
General comments (publicly viewable) (Max 1000 characters): JMF20-017

Test was verified on 11/13/2020