Summary for Test 2020-04-17-17-9

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214628
DEA: 031G6604
EFIS: 0319000116
DIST-CO-RTE-PM03-BUT-162-12.6/15.6
Award Date03/17/2020
Closeout Date07/09/2021
Work DescriptionCOLD IN-PLACE RECYCLING, RHMA-G OVERLAY, AND COLD PLANE AC PAVEMENT.
Location DescriptionBUTTE COUNTY IN AND NEAR OROVILLE FROM 0.8 MILE EAST OF WILBUR ROAD TO FEATHER RIVER BRIDGE
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date04/17/2020 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing04/20/2020 Sample typeVerification
A brief description of the sample1/2 inch RHMA-G The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byKenny
Last name of sampler or witnessed byMcHugh Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert-Hallwood Drum Plant
Transportation Laboratory (TL) NumberC779100 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-58-0006::HALLWOOD PLANT
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedcold feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-17-17
DIME Test ID: 2020-04-17-17-9
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-11-13

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 05/26/2020
Cumulative Percent Passing
%
100 %
100 %
100 %
99 %
92 %
39 %
22 %
15 %
11 %
8 %
5 %
3.3 %
General comments (publicly viewable) (Max 1000 characters): JMF20-017. Test date estimated

Test was verified on 11/13/2020 ✔