Summary for Test 2020-06-18-48-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214797
DEA: 031G2504
EFIS: 0318000107
DIST-CO-RTE-PM03-ED-193-19.3/R24.7
Award Date05/19/2020
Closeout Date03/16/2021
Work DescriptionCOLD PLANE AC PAVEMENT, RHMA-G OVERLAY, & REPLACE GUARDRAIL.
Location DescriptionEL DORADO COUNTY NEAR PLACERVILLE FROM 0.1 MILE NORTH OF GARDEN VALLEY ROAD TO SOUTH FORK AMERICAN RIVER BRIDGE
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date06/18/2020 Sample Unique Key48
Date that the sample was received by the laboratory/organization performing the testing06/19/2020 Sample typeVerification
A brief description of the sample1/2 inch RHMA-G The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byGRI Personnel
Last name of sampler or witnessed byGRI Personnel Title of samplerGRI Personnel
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGeorge Reed - Clements Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-06-18-48
DIME Test ID: 2020-06-18-48-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-11-06

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Terrance White
Date of test: 07/30/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1761.4 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 7.70 %
General comments (publicly viewable) (Max 1000 characters): JMF20-012B

Test was verified on 11/6/2020 ✔