Summary for Test 2020-10-29-2-2

Test performed: ASTM C39-18

Project Information

Project IdentifiersProject ID: 213700
DEA: 020H9004
EFIS: 0215000077
DIST-CO-RTE-PM02-BUT-70-41.9/42.3
Award Date05/07/2020
Closeout Date11/01/2021
Work DescriptionREMOVE CULVERTS AND CONSTRUCT BRIDGE
Location DescriptionBUTTE COUNTY NEAR PULGA FROM 2.5 MILES WEST OF PENSTOCK UNDERCROSSING TO 2.1 MILES WEST OF PENSTOCK UNDERCROSSING
QA Service Level1 (Verified on 01/03/2019)

Sample Information

Sample Taken Date10/29/2020 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing10/29/2020 Sample typeQuality Control
A brief description of the samplePCC 6"x12" test cylinder The quantity of what the sample constitutes1 girder
From where was the sample collectedManufacturer First name of sampler or witnessed byRoberto
Last name of sampler or witnessed byReyes Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCon-Fab California, LLC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCC-S98-25FA
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2629
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2020-10-29-2
DIME Test ID: 2020-10-29-2-2
Testing Lab: Con-Fab California Corporation - Shafter
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-11-04

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Roberto Reyes Perez
Date of test: 10/30/2020
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Capped in accordance with?: ASTM C1231
Maximum load on cylinder 1: 147745 lb
Maximum load on cylinder 2: 145490 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 1 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5190 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/4/2020 ✔