Summary for Test 2020-10-12-46-1

Test performed: AASHTO T59-16
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 214388
DEA: 051F6804
EFIS: 0514000046
DIST-CO-RTE-PM05-MON-1-39.8/74.6
Award Date11/05/2019
Closeout Date08/17/2022
Work DescriptionRHMA OVERLAY ON EXISTING ROADWAY AND REPLACE GUARDRAIL.
Location DescriptionMONTEREY COUNTY FROM TORRE CANYON BRIDGE NEAR BIG SUR TO SAN LUIS AVENUE IN CARMEL
QA Service Level1 (Verified on 09/06/2019)

Sample Information

Sample Taken Date10/12/2020 Sample Unique Key46
Date that the sample was received by the laboratory/organization performing the testing10/26/2020 Sample typeDepartment Acceptance
A brief description of the sampleEMULSION The quantity of what the sample constitutes1 jug
From where was the sample collectedJob Site First name of sampler or witnessed byunknown
Last name of sampler or witnessed byUnknown Title of samplerQC
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePacific Northwest Oil - Stockton, CA
Transportation Laboratory (TL) Number972763 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2020-10-12-46
DIME Test ID: 2020-10-12-46-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Residue and Oil Distillate (Sec. 6))
Test Release Date: 2020-10-29

Test Results


What parameters are being calculated?: Percentage of oil residue
Is this a polymer-modified emulsion: No
Input Type: Measured
Tester's full name: Sunday Agude
Date of test: 10/29/2020
Mass of the distillation pot, accessories, and reside after the test: 446.0 g
Mass of distillation pot and accessories before test: 416.2 g
Correction Factor: 1.5
Mass of the distallation pot, accessories, and reside after the test w/ correction factor: 447.5 g
Percentage of oil residue: 15.7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/29/2020 ✔

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.