Summary for Test 2020-10-29-1-1

Test performed: AASHTO T27-14
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date10/29/2020 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing10/29/2020 Sample typeQuality Control
A brief description of the sampleINFILTRATION TEST/RETAINING WALLStest The quantity of what the sample constitutestest
From where was the sample collectedJob Site First name of sampler or witnessed bytest
Last name of sampler or witnessed bytest Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nametest
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedtest
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-10-29-1
DIME Test ID: 2020-10-29-1-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-10-29

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 10/29/2020
Cumulative Percent Passing
%
100 %
100 %
100 %
100 %
97 %
86 %
75 %
65 %
50 %
30 %
20 %
12 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/29/2020 ✔

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.