Summary for Test 2020-10-20-7-1

Test performed: ASTM D217-16
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 213469
DEA: 024C40V4
EFIS: 0218000125
DIST-CO-RTE-PM02-SHA-5-R3.8/R11.7
Award Date11/06/2018
Closeout Date08/16/2023
Work DescriptionWIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB
Location DescriptionSHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING
QA Service Level1 (Verified on 12/31/2018)

Sample Information

Sample Taken Date10/20/2020 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing10/23/2020 Sample typeVerification
A brief description of the sampleAsphalt Rubber Binder The quantity of what the sample constitutesARB Rcvd 2 cans #21 Test
From where was the sample collectedSource First name of sampler or witnessed byC
Last name of sampler or witnessed byBryant Title of samplerTET
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameValero
Transportation Laboratory (TL) Number853473 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-10-20-7
DIME Test ID: 2020-10-20-7-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2020-10-29

Test Results


Determination: Unworked Penetration
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 10/27/2020
Unworked Penetration, Test 1: 33 0.1 mm
Unworked Penetration, Test 2: 32 0.1 mm
Unworked Penetration, Test 3: 32 0.1 mm
Unworked Penetration: 32 0.1 mm
General comments (publicly viewable) (Max 1000 characters): As per 2018 Standard Spec.

Test was verified on 10/29/2020 ✔

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.