Summary for Test 2020-09-15-21-4
Test performed: AASHTO T315-16Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/15/2020 | Sample Unique Key | 21 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/26/2020 | Sample type | Verification |
| A brief description of the sample | rcvd 4 cans of multigrade PG 64-10/16 | The quantity of what the sample constitutes | 1 Can |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Don |
| Last name of sampler or witnessed by | Powell | Title of sampler | |
| Telephone number of sampler | 661-327-8248 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | San Joaquin Refinery, Bakersfield, CA | |
| Transportation Laboratory (TL) Number | 20641631 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | Not set | |
| Time of sample | Not set | HMA Supplier | Not set |
| Certified Asphalt Supplier | Not set | Multigrade | Not set |
| Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2020-09-15-21
DIME Test ID: 2020-09-15-21-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-10-27
Test Results
Phase: RTFO residue
Input Type: Measured
Tester's full name: Doug Ruff
Date of test: 10/27/2020
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.226 kPa
Phase Angle (δ) (for the 10 cycles): 88.5 degree
Complex Modulus (G*) (for the 10 measurements): 2.263 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 2.26 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standards and Specifications
Test was verified on 10/27/2020 ✔