Summary for Test 2020-10-16-1-7
Test performed: ASTM D4791-10Project Information
| Project Identifiers | Project ID: 213306 DEA: 07303404 EFIS: 0714000006 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-33-0.0/6.3 |
| Award Date | 06/18/2018 |
| Closeout Date | 05/10/2021 |
| Work Description | COLD PLANE AC PVMT, PLACE RUBBERIZED AC (TYPE G), AND REPLACE PCC PVMT |
| Location Description | VENTURA COUNTY IN AND NEAR VENTURA FROM ROUTE 33/101 SEPARATION TO 0.1 MILE SOUTH OF PARK VIEW DRIVE |
| QA Service Level | 1 (Verified on 12/09/2020) |
Sample Information
| Sample Taken Date | 10/16/2020 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/17/2020 | Sample type | Verification |
| A brief description of the sample | PSUE 3/4" HMA-A-SP R15 | The quantity of what the sample constitutes | 5 Bags Of Agg., 1 Bag Of Rap |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | MD |
| Last name of sampler or witnessed by | Shajahan | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0612A-20 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Sun Valley | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0035::FISH CANYON QUARRY |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | 3/4 HMA-A-SP R15 | The fabricator/manufacturer designation for the sample | |
| The plant number | 220831 SVA MPC | A detailed description of where the material sample was collected | Belt Cut at Vulcan Sun Valley Plant |
| Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-10-16-1
DIME Test ID: 2020-10-16-1-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-10-26
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 10/20/2020
Weighted percentage of particles (by mass) that were flat and elongated: 0 %
Weighted percentage of particles (by mass) that were not flat and elongated: 100 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/26/2020 ✔