Summary for Test 2020-10-16-1-3

Test performed: AASHTO T85-13

Project Information

Project IdentifiersProject ID: 213306
DEA: 07303404
EFIS: 0714000006
DIST-CO-RTE-PM07-VEN-33-0.0/6.3
Award Date06/18/2018
Closeout Date05/10/2021
Work DescriptionCOLD PLANE AC PVMT, PLACE RUBBERIZED AC (TYPE G), AND REPLACE PCC PVMT
Location DescriptionVENTURA COUNTY IN AND NEAR VENTURA FROM ROUTE 33/101 SEPARATION TO 0.1 MILE SOUTH OF PARK VIEW DRIVE
QA Service Level1 (Verified on 12/09/2020)

Sample Information

Sample Taken Date10/16/2020 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing10/17/2020 Sample typeVerification
A brief description of the samplePSUE 3/4" HMA-A-SP R15 The quantity of what the sample constitutes5 Bags Of Agg., 1 Bag Of Rap
From where was the sample collectedManufacturer First name of sampler or witnessed byMD
Last name of sampler or witnessed byShajahan Title of sampler
Telephone number of sampler Laboratory sample identification0612A-20
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Sun Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035::FISH CANYON QUARRY
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number220831 SVA MPC A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-10-16-1
DIME Test ID: 2020-10-16-1-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Test Release Date: 2020-10-26

Test Results


Basis for relative density testing: Bulk
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 10/20/2020
Mass of sample saturated surface dry aggregate: 3122 grams
Mass of sample in water: 1974 grams
Mass of sample after oven drying: 3090 grams
Specific Gravity: 2.692
Absorption: 1.0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/26/2020 ✔