Summary for Test 2020-10-09-12-5

Test performed: CTM 551-August 2012

Project Information

Project IdentifiersProject ID: 214903
DEA: 074W5404
EFIS: 0719000003
DIST-CO-RTE-PM07-LA-14,138-VAR
Award Date05/29/2020
Closeout Date03/15/2021
Work DescriptionPOLYESTER CONCRETE OVERLAY, APPLY METHCRYLATE & REPLACE JOINT SEALS.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/15/2021)

Sample Information

Sample Taken Date10/09/2020 Sample Unique Key12
Date that the sample was received by the laboratory/organization performing the testing10/09/2020 Sample typeQuality Control
A brief description of the sample1 gallon can The quantity of what the sample constitutes2 Tankers
From where was the sample collectedSource First name of sampler or witnessed byDaniel
Last name of sampler or witnessed byTikusis Title of samplerTechnical Director
Telephone number of sampler707-330-9227 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameKwik Bond Polymers and Polynt
Transportation Laboratory (TL) NumberSacramento Caltrans lab Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1283100
Batch Number1283100 Mix number1283100

Test Details

DIME Sample ID: 2020-10-09-12
DIME Test ID: 2020-10-09-12-5
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Test Release Date: 2020-10-21

Test Results


Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 10/21/2020
Curing history for Sample 1: 24hr
Maximum applied load (P) for Sample 1: 1850 lb
Span length for Sample 1: 9 in
Break location for Sample 1: bond
Specimen defects/notes for Sample 1: no data
Surface type for Sample 1: SSD
Modulus of rupture (R) for Sample 1: 925 psi
Curing history for Sample 2: 24hr
Maximum applied load (P) for Sample 2: 1696 lb
Span length for Sample 2: 9 in
Break location for Sample 2: bond
Specimen defects/notes for Sample 2: no data
Surface type for Sample 2: SSD
Modulus of rupture (R) for Sample 2: 848 psi
Curing history for Sample 3: 24hr
Maximum applied load (P) for Sample 3: 1356 lb
Span length for Sample 3: 9 in
Break location for Sample 3: bond
Specimen defects/notes for Sample 3: no data
Surface type for Sample 3: SSD
Modulus of rupture (R) for Sample 3: 678 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/21/2020 ✔