Summary for Test 2020-10-09-17-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212501
DEA: 022E4804
EFIS: 0200000586
DIST-CO-RTE-PM02-SIS-96,263-103.1/103.6,56.8/57.2
Award Date12/14/2018
Closeout Date12/01/2021
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 8 MILES NORTH OF YREKA ON ROUTE 96 FROM 0.5 MILE WEST TO 0.2 MILE EAST OF ROUTE 263 AND ON ROUTE 263 FROM 0.3 MILE NORTH OF SHASTA RIVER BRIDGE #02-0014 TO ROUTE 96
QA Service Level1 (Verified on 06/06/2017)

Sample Information

Sample Taken Date10/09/2020 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing10/20/2020 Sample typeQuality Assurance
A brief description of the sample Bar Lock Standard Black Couplers The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byPETER
Last name of sampler or witnessed byGAN Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNucor Dayton Superior
Transportation Laboratory (TL) NumberC858378 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelBar Lock Stanard Black Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)182833 Rebar Heat Number(s)3500011779
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2020-10-09-17
DIME Test ID: 2020-10-09-17-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-10-20

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 10/20/2020
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 8/25mm100.797746398055Service splicebewing

General comments (publicly viewable) (Max 1000 characters): Service splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 10/20/2020 ✔