Summary for Test 2020-09-25-23-8
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 214588 DEA: 020J1504 EFIS: 0219000066 |
---|---|
DIST-CO-RTE-PM | 02-SHA,TEH-36-4.0/8.0,13.0/17.0 |
Award Date | 02/20/2020 |
Closeout Date | 01/05/2021 |
Work Description | PLACE HMA (TYPE A), REPLACE AC SURFACING AND GUARDRAIL. |
Location Description | SHASTA AND TEHAMA COUNTIES NEAR PLATINA FROM 0.3 MILE EAST OF HARRISON GULCH ROAD TO 0.8 MILE WEST OF PLATINA ROAD AND FROM 2.6 MILES EAST OF DRY CREEK BRIDGE TO 2.1 MILES WEST OF SALT CREEK BRIDGE |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 09/25/2020 | Sample Unique Key | 23 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/09/2020 |
Sample type | Department Acceptance | A brief description of the sample | AB PG 58-34 M #5 Test, #3(851370), #4(851371), No Test |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | Derell | Last name of sampler or witnessed by | Harper |
Title of sampler | Consultant | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | valero benicia | Transportation Laboratory (TL) Number | 851372 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | Not set | |
Time of sample | Not set | HMA Supplier | Not set |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-09-25-23
DIME Test ID: 2020-09-25-23-8
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-10-13
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Doug Ruff
Date of test: 10/12/2020
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.287 kPa
Phase Angle (δ) (for the 10 cycles): 63.0 degree
Complex Modulus (G*) (for the 10 measurements): 2.393 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 2.69 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard and Specifications
Test was verified on 10/13/2020 ✔