Summary for Test 2020-09-06-1-3
Test performed: AASHTO T315-16Project Information
| Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/06/2020 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/07/2020 |
| Sample type | Verification | A brief description of the sample | Asphalt Binder Sample |
| The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Eric | Last name of sampler or witnessed by | Gauss |
| Title of sampler | Telephone number of sampler | 310-518-4000 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Valero-Wilmington | Transportation Laboratory (TL) Number | 090620-761-470 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | Not set | |
| Time of sample | Not set | HMA Supplier | Not set |
| Certified Asphalt Supplier | Not set | Multigrade | Not set |
| Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-09-06-1
DIME Test ID: 2020-09-06-1-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-10-08
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Doug Ruff
Date of test: 10/08/2020
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.167 kPa
Phase Angle (δ) (for the 10 cycles): 86.7 degree
Complex Modulus (G*) (for the 10 measurements): 1.389 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.39 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 standard specifications
Test was verified on 10/8/2020 ✔