Summary for Test 2020-09-02-30-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 214876
DEA: 060W7604
EFIS: 0617000279
DIST-CO-RTE-PM06-KER,TUL-63,65,216-Var
Award Date04/30/2020
Closeout Date04/29/2021
Work DescriptionCOLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE RHMA-G.
Location DescriptionKERN AND TULARE COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/21/2020)

Sample Information

Sample Taken Date09/02/2020 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing09/28/2020 Sample typeDepartment Acceptance
A brief description of the sample#15 Test, No Test #14(815326), #16(815326-2, #17(815326-3), #18(815326-4), #19(815326-5) The quantity of what the sample constitutes1 Can
From where was the sample collectedJob Site First name of sampler or witnessed byJason
Last name of sampler or witnessed byrnit Title of samplerConsultant
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namedeer creek asphalt
Transportation Laboratory (TL) Number865163 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-09-02-30
DIME Test ID: 2020-09-02-30-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2020-10-08

Test Results


Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 10/07/2020
Temperature: 25 C
Ball Penetration (P1): 0 mm
Final Dial reading (F1): 75 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F2): 70 mm
Ball Penetration (P3): 0 mm
Final Dial reading (F3): 70 mm
Resilience 1: 25 %
Resilience 2: 30 %
Resilience 3: 30 %
Average Resilience: 28 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 standard specifications

Test was verified on 10/8/2020 ✔