Summary for Test 2020-09-02-30-2
Test performed: ASTM D36-14ε1Project Information
| Project Identifiers | Project ID: 214876 DEA: 060W7604 EFIS: 0617000279 |
|---|---|
| DIST-CO-RTE-PM | 06-KER,TUL-63,65,216-Var |
| Award Date | 04/30/2020 |
| Closeout Date | 04/29/2021 |
| Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE RHMA-G. |
| Location Description | KERN AND TULARE COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 04/21/2020) |
Sample Information
| Sample Taken Date | 09/02/2020 | Sample Unique Key | 30 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/28/2020 |
| Sample type | Department Acceptance | A brief description of the sample | #15 Test, No Test #14(815326), #16(815326-2, #17(815326-3), #18(815326-4), #19(815326-5) |
| The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jason | Last name of sampler or witnessed by | rnit |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | deer creek asphalt | Transportation Laboratory (TL) Number | 865163 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-09-02-30
DIME Test ID: 2020-09-02-30-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2020-10-08
Test Results
ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 10/08/2020
Softening Point Sample 1: 70 C
Softening Point Sample 2: 70 C
Bath Liquid: USP glycerin
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 standard specifications
Test was verified on 10/8/2020 ✔