Summary for Test 2020-06-18-41-3
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 214571 DEA: 020J1104 EFIS: 0219000062 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-33.1/42.1 |
| Award Date | 02/07/2020 |
| Closeout Date | 04/27/2021 |
| Work Description | PLACE HMA & SHOULDER BACKING, & REMOVE & REPLACE PAVEMENT DELINEATION. |
| Location Description | PLUMAS COUNTY AT AND NEAR KEDDIE FROM INDIAN CREEK BRIDGE TO 0.3 MILE WEST OF SPANISH CREEK BRIDGE NO. 09-0018 |
| QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
| Sample Taken Date | 06/18/2020 | Sample Unique Key | 41 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/18/2020 | Sample type | Verification |
| A brief description of the sample | Combined RAP (1/2-inch) | The quantity of what the sample constitutes | JMF Verification |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | PEI |
| Last name of sampler or witnessed by | Joe | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | D78487B | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Sierra Cascade Aggregate and Asphalt Products | |
| Transportation Laboratory (TL) Number | 734737 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Sierra Cascade |
|---|---|---|---|
| Aggregate Size | 1/2-inch | Aggregate Source | |
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-18-41
DIME Test ID: 2020-06-18-41-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2020-10-02
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/20/2020
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7338 grams
Mass of oven-dry sample in air for Sample 1: 1568 grams
Mass of container filled with the sample and water for Sample 1: 8277 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.494
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/2/2020 ✔