Summary for Test 2020-09-02-12-2
Test performed: AASHTO T51-13Project Information
| Project Identifiers | Project ID: 214834 DEA: 010G1304 EFIS: 0116000128 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-199-10.2/10.7 |
| Award Date | 05/06/2020 |
| Closeout Date | 01/06/2021 |
| Work Description | PLACE HMA AND HIGH FRICTION SURFACE TREATMENT. |
| Location Description | DEL NORTE COUNTY NEAR GASQUET FROM 0.7 MILE TO 0.3 MILE SOUTH OF HARDSCRABBLE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 06/03/2020) |
Sample Information
| Sample Taken Date | 09/02/2020 | Sample Unique Key | 12 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/10/2020 | Sample type | Department Acceptance |
| A brief description of the sample | Pg 64-16 #1 test | The quantity of what the sample constitutes | 1 can |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | kanneth |
| Last name of sampler or witnessed by | Sutterfield | Title of sampler | ARE |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | S T Rhoades | |
| Transportation Laboratory (TL) Number | 944529 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | Not set | |
| Time of sample | Not set | HMA Supplier | Not set |
| Certified Asphalt Supplier | Not set | Multigrade | Not set |
| Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2020-09-02-12
DIME Test ID: 2020-09-02-12-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2020-09-28
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 09/23/2020
Ductility of test #1 (D1): 75 cm
Ductility of sample: 75 cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/28/2020 ✔