Summary for Test 2020-08-14-30-3
Test performed: AASHTO T96-02r10Project Information
| Project Identifiers | Project ID: 214658 DEA: 051K7104 EFIS: 0518000232 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-46,101-var |
| Award Date | 04/28/2020 |
| Closeout Date | 08/23/2021 |
| Work Description | PLACE METHACRYLATE DECK SEAL, POLYESTER CONCRETE OVERLAY, JOINT SEALS |
| Location Description | SAN LUIS OBISPO COUNTY IN AND NEAR PASO ROBLES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 02/20/2020) |
Sample Information
| Sample Taken Date | 08/14/2020 | Sample Unique Key | 30 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/09/2020 | Sample type | Verification |
| A brief description of the sample | Bags of Aggregate | The quantity of what the sample constitutes | One JMF Verification |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Mike |
| Last name of sampler or witnessed by | Savage | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | SPM Templeton | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0006 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | At the Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-08-14-30
DIME Test ID: 2020-08-14-30-3
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-09-25
Test Results
Input Type: Calculated
Tester's full name: Historical
Date of test: 09/25/2020
Grading designation: B
Percent loss after 100 revolutions: 7 %
Percent loss after 500 revolutions: 28 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/25/2020 ✔