Summary for Test 2014-12-11-1-1
Test performed: CTM 643-June 2007Project Information
| Project Identifiers | Project ID: 210199 DEA: 07286304 EFIS: 0713000216 |
|---|---|
| DIST-CO-RTE-PM | 07-LA--66/70 |
| Award Date | 05/19/2026 |
| Closeout Date | Not set |
| Work Description | Widen Route 138 to 4 lanes with a median turn lane and standard width shoulder. |
| Location Description | IN LOS ANGELES COUNTY IN PALMDALE FROM 0.4 MILE WEST OF 190TH STREET EAST TO ROUTE 18 JUNCTION |
| QA Service Level | 1 (Verified on 08/28/2026) |
Sample Information
| Sample Taken Date | 12/11/2014 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/11/2014 | Sample type | Preliminary |
| A brief description of the sample | Soil | The quantity of what the sample constitutes | 1 Bag |
| From where was the sample collected | Source | First name of sampler or witnessed by | Kristopher |
| Last name of sampler or witnessed by | Barker | Title of sampler | Engineering Geologist |
| Telephone number of sampler | Unknown | Laboratory sample identification | 4333B |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | A 14 001 Bulk |
| Transportation Laboratory (TL) Number | C707710 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | A 14 001 Bulk |
| Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2014-12-11-1
DIME Test ID: 2014-12-11-1-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2015-02-23
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Measured
Tester's full name: Vincent Onoh
Date of test: 01/06/2015
Soil sample resistance (lab measure 1): 3600 Ohms
Soil sample resistance (lab measure 2): 3700 Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 3600 Ohms
Soil sample temperature: 19.7 C
Soil box constant: 1
pH of soil: 8.66
Minimum soil resistance corrected to 15.5: 3978 Ohms
Minimum soil resistivity at 15.5: 3978 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/23/2015 ✔