Summary for Test 2020-09-15-4-4

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 212914
DEA: 031E0604
EFIS: 0312000068
DIST-CO-RTE-PM03-YUB-70-15.5/16.5
Award Date07/31/2019
Closeout Date08/30/2023
Work DescriptionSIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055.
Location DescriptionNEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019.
QA Service Level1 (Verified on 08/22/2019)

Sample Information

Sample Taken Date09/15/2020 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing09/16/2020 Sample typeQuality Assurance
A brief description of the samplePrestressing Strand The quantity of what the sample constitutes96
From where was the sample collectedManufacturer First name of sampler or witnessed byDon
Last name of sampler or witnessed byHiranaga Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSumiden Wire
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s) Number of Coils
Group Number10945, 10946, 10947 Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0559220, S0558320, S0559120, S0520020-2 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2020-09-15-4
DIME Test ID: 2020-09-15-4-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2020-09-17

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/17/2020
UTM: 120kip
Temperature: 72 f
Extensometers: no data
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0558320S379330-40.2146137056552.429.11.78bewing

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 9/17/2020 ✔