Summary for Test 2020-08-13-19-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 214756
DEA: 050N7AU4
EFIS: 0520000030
DIST-CO-RTE-PM05-SB-101-1.4/4.8
Award DateNot set
Closeout Date09/27/2022
Work DescriptionSegment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location DescriptionCARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
QA Service Level1 (Verified on 03/09/2020)

Sample Information

Sample Taken Date08/13/2020 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing08/14/2020 Sample typeQuality Control
A brief description of the sampleConcrete The quantity of what the sample constitutes100 cy
From where was the sample collectedJob Site First name of sampler or witnessed byJerome
Last name of sampler or witnessed byAyers Title of samplerField Technician
Telephone number of sampler Laboratory sample identificationC081320-401
Linked DIME Sample ID The fabricator/manufacturer/facility nameHanson Goleta
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameSound Wall 4C Pile Cap
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number63511N0P
The truck number from where the sample was collected528 The batch plant ticket number from where the sample was collected543621
Concrete batch plantHanson Goleta The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedReady Mix Chute Where the material sample would have been placed if not sampledSound Wall 4C
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2020-08-13-19
DIME Test ID: 2020-08-13-19-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2020-09-16

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Carlos Fuentes
Date of test: 09/10/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 119180 lb
Maximum load on cylinder 2: 120060 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4240 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/16/2020 ✔