Summary for Test 2020-07-10-34-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 214756
DEA: 050N7AU4
EFIS: 0520000030
DIST-CO-RTE-PM05-SB-101-1.4/4.8
Award DateNot set
Closeout Date09/27/2022
Work DescriptionSegment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location DescriptionCARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
QA Service Level1 (Verified on 03/09/2020)

Sample Information

Sample Taken Date07/10/2020 Sample Unique Key34
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/13/2020
Sample typeQuality Control A brief description of the sample1x4 concrete aggregates
The quantity of what the sample constitutes200 cy From where was the sample collectedSource
First name of sampler or witnessed byJosh Last name of sampler or witnessed byHua
Title of samplerField Technician Telephone number of sampler
Laboratory sample identificationS071020-203 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHanson Goleta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier51-0353
Structure nameFranklin Creek Bridge Deck

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-40-0003
The fabricator's/manufacturer's product name for the sampleCT-675C The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampledFranklin Creek Bridge Deck Primary Aggregate Nominal Size1 inch
The concrete mix design number72F1S0Z Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-10-34
DIME Test ID: 2020-07-10-34-1
Testing Lab: Sequoia Consultants
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-09-16

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Leo Santamaria
Date of test: 07/13/2020
Cumulative percent passing the 1 1/2 in. sieve: 0 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 81 %
Cumulative percent passing the 1/2 in. sieve: 36 %
Cumulative percent passing the 3/8 in. sieve: 21 %
Cumulative percent passing the #4 sieve: 4 %
Cumulative percent passing the #8 sieve: 2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/16/2020