Summary for Test 2020-09-11-1-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214176
DEA: 033F0904
EFIS: 0312000056
DIST-CO-RTE-PM03-SAC,SJ-5,160-Var
Award Date10/10/2019
Closeout Date10/27/2022
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGES, PLACE CIDH & CISS CONCRETE PILES.
Location DescriptionSACRAMENTO COUNTY AT NORTH SACRAMENTO UNDERCROSSING AND SACRAMENTO RIVER BRIDGE AND IN SAN JOAQUIN COUNTY AT MOKELUMNE RIVER BRIDGE
QA Service Level1 (Verified on 05/29/2019)

Sample Information

Sample Taken Date09/11/2020 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing09/14/2020 Sample typeQuality Assurance
A brief description of the sampleHRC 500 510 Couplers The quantity of what the sample constituteslot of 150 bars
From where was the sample collectedFabricator First name of sampler or witnessed bySaman
Last name of sampler or witnessed byBarzegari Title of samplerAssistant Materials Representative
Telephone number of sampler9162134973 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCamblin Steel Service, Benicia
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB384-003-20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor Seattle
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#7 Coupler ModelHRC 500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)500 / 73112579 510 / 73112579 Rebar Heat Number(s)3500009524
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2020-09-11-1
DIME Test ID: 2020-09-11-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-09-14

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/14/2020
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 7/22mm100.65834897246OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 9/14/2020 ✔