Summary for Test 2020-09-08-17-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214605
DEA: 051K7904
EFIS: 0519000026
DIST-CO-RTE-PM05-SB-166-R51.1/55.0
Award Date02/26/2020
Closeout Date08/23/2021
Work DescriptionCOLD IN-PLACE RECYCLING AND RHMA OVERLAY.
Location DescriptionSANTA BARBARA COUNTY ABOUT 10 MILES WEST OF NEW CUYAMA FROM CUYAMA RIVER BRIDGE TO 3.1 MILES EAST OF COTTONWOOD CANYON ROAD
QA Service Level1 (Verified on 04/08/2020)

Sample Information

Sample Taken Date09/08/2020 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing09/09/2020 Sample typeDepartment Acceptance
A brief description of the sample3/4" RHMA-G w/LSM The quantity of what the sample constitutes4 boxes
From where was the sample collectedManufacturer First name of sampler or witnessed byMark
Last name of sampler or witnessed byBennett Title of sampler
Telephone number of sampler Laboratory sample identification20-A-227
Linked DIME Sample ID The fabricator/manufacturer/facility nameCal Portland Garey Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number13 HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-09-08-17
DIME Test ID: 2020-09-08-17-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-09-11

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Eric Atkins
Date of test: 09/10/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: no data F
Corrected Asphalt Binder Content: 7.51 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/11/2020 ✔