Summary for Test 2020-07-24-23-4
Test performed: AASHTO T315-16Project Information
| Project Identifiers | Project ID: 214684 DEA: 020J1404 EFIS: 0219000065 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-96,263-VAR |
| Award Date | 04/15/2020 |
| Closeout Date | 10/22/2020 |
| Work Description | PLACE HMA OVERLAY, GUARDRAIL, SHOULDER BACKING, REPLACE AC SURFACING. |
| Location Description | SISKIYOU COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
| Sample Taken Date | 07/24/2020 | Sample Unique Key | 23 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/31/2020 | Sample type | Department Acceptance |
| A brief description of the sample | Asphalt Binder PG 58-34M | The quantity of what the sample constitutes | 1 Can #1 Test (854825) |
| From where was the sample collected | Source | First name of sampler or witnessed by | Juan |
| Last name of sampler or witnessed by | M | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | JF Shea Yreka | |
| Transportation Laboratory (TL) Number | 854825 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
|---|---|---|---|
| Modified | Yes | Lot number | |
| Sublot number | Tank number | Not set | |
| Time of sample | Not set | HMA Supplier | Not set |
| Certified Asphalt Supplier | Not set | Multigrade | Not set |
| Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2020-07-24-23
DIME Test ID: 2020-07-24-23-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-09-02
Test Results
Phase: PAV residue
Input Type: Calculated
Tester's full name: Xavier Carrillo
Date of test: 09/02/2020
Test Plate Diameter: 8 mm
Phase Angle (δ) (for the 10 cycles): 43.3 degree
(G*) x sin(δ)=: 4688 kPa
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/2/2020 ✔