Summary for Test 2020-08-28-2-1

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 214511
DEA: 010E0004
EFIS: 0113000091
DIST-CO-RTE-PM01-HUM-101-84.4/84.8
Award Date01/29/2020
Closeout Date11/22/2023
Work DescriptionBRIDGE RAIL REPLACEMENT.
Location DescriptionHUMBOLDT COUNTY NEAR ARCATA FROM JACOBY CREEK BRIDGE TO GANNON SLOUGH BRIDGE
QA Service Level1 (Verified on 11/13/2019)

Sample Information

Sample Taken Date08/28/2020 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing08/31/2020 Sample typeQuality Assurance
A brief description of the sample1 3/8" threaded rod with HHN The quantity of what the sample constitutes15
From where was the sample collectedManufacturer First name of sampler or witnessed bySteve
Last name of sampler or witnessed byHall Title of samplerCT METS QA INSPECTOR
Telephone number of sampler6466327821 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameWilliams Form Engineering-SD
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL134-182-20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade18
Threaded Bar TypePlain Rebar Size#11
Nut Specification for Threaded BarASTM A 29 System ManufacturerSchwager Davis
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)62151303-04
Nut Heat Number(s)74116251 Bar Lot NumberN/A
Nut Lot Number36E3D Coupler Heat Number(s)N/A
Coupler GradeN/A

Test Details

DIME Sample ID: 2020-08-28-2
DIME Test ID: 2020-08-28-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2020-09-02

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/02/2020
UTM: 2000kip
Temperature: 72 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
11ASTM A722 Type II Deformed Bar 1 3/8 : 36mm11.503165998.02145.39032.3A722 Threaded Bar and Nutbewing

General comments (publicly viewable) (Max 1000 characters): A722 Threaded Bar and Nut
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.

Test was verified on 9/2/2020 ✔