Summary for Test 2020-08-27-5-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 213741
DEA: 07325704
EFIS: 0716000089
DIST-CO-RTE-PM07-LA-5-1.7
Award DateNot set
Closeout DateNot set
Work DescriptionBUILDING CONSTRUCTION IN LOS ANGELES COUNTY IN SANTA FE SPRINGS AT 14044 FREEWAY DRIVE.
Location DescriptionSanta Fe Springs, At 14044 Freeway Drive.
QA Service Level1 (Verified on 07/08/2019)

Sample Information

Sample Taken Date08/27/2020 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing08/31/2020 Sample typeQuality Assurance
A brief description of the sample3/4" x 4" TC Bolt assembly The quantity of what the sample constitutes20
From where was the sample collectedDistributor First name of sampler or witnessed bySteve
Last name of sampler or witnessed byHall Title of samplerCT METS QA INSPECTOR
Telephone number of sampler6466327821 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBristol Machine
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL134-180-20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)Bolt 20554750 Nut 188310 Washer 173610 Nut Mfg. Lot Number(s)28389-188310
Washer Mfg. Lot Number(s)D5239 Bolt SpecificationASTM F1852
Bolt Length(s)4" Nut SpecificationASTM A563 Gr. DH
Washer SpecificationASTM F436 FinishBlack
Diameter/Size5/8" Bolt Mfg. Lot Number28311-20554750
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2020-08-27-5
DIME Test ID: 2020-08-27-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-09-01

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 08/31/2020
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A28389-18831061306Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 9/1/2020 ✔