Summary for Test 2020-08-24-3-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 214702
DEA: 030F2864
EFIS: 0320000123
DIST-CO-RTE-PM03-SAC-99-7.92 / 8.4
Award Date06/24/2020
Closeout Date11/28/2023
Work DescriptionRemove and replace Consumnes River and Consumnes River Overflow bridge
Location DescriptionSacramento County
QA Service Level1 (Verified on 04/20/2020)

Sample Information

Sample Taken Date08/24/2020 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing08/24/2020 Sample typeQuality Control
A brief description of the samplePCC 6''x12'' test cylinder The quantity of what the sample constitutes1 girder
From where was the sample collectedManufacturer First name of sampler or witnessed byJorge
Last name of sampler or witnessed byGarcia Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCon-Fab California, LLC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameCosumnes River Overflow Bridge
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCC-S98-10F
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2365
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2020-08-24-3
DIME Test ID: 2020-08-24-3-1
Testing Lab: Con-Fab California Corporation - Shafter
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-09-17

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jorge Garcia
Date of test: 08/26/2020
Capped in accordance with?: ASTM C1231
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 178065 lb
Maximum load on cylinder 2: 174285 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 2 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 6230 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/17/2020