Summary for Test 2020-06-10-39-2
Test performed: AASHTO T30-19Project Information
Project Identifiers | Project ID: 212866 DEA: 021H9704 EFIS: 0216000051 |
---|---|
DIST-CO-RTE-PM | 02-TEH-36-12.6/13.1 |
Award Date | 11/25/2019 |
Closeout Date | 10/06/2020 |
Work Description | CURVE REALIGNMENT AND HMA PAVING. |
Location Description | TEHAMA COUNTY ABOUT 16 MILES EAST OF PLATINA FROM 2.3 MILES EAST TO 2.8 MILES EAST OF DRY CREEK BRIDGE |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 06/10/2020 | Sample Unique Key | 39 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/10/2020 |
Sample type | Verification | A brief description of the sample | Combined RAP, 1/2-inch |
The quantity of what the sample constitutes | JMF Renewal and PSE | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Dave | Last name of sampler or witnessed by | Lockett |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78462B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Northstate Asphalt, Redding, CA | Transportation Laboratory (TL) Number | 736619 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Northstate |
---|---|---|---|
Aggregate Size | 1/2-inch | Aggregate Source | |
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-10-39
DIME Test ID: 2020-06-10-39-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2020-08-28
Test Results
Does this test use 1/4 sieve?: Yes
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/12/2020
Cumulative Mass Retained | Cumulative Percent Passing | |||||
---|---|---|---|---|---|---|
1571.7 grams | ||||||
0.0 grams | 100 % | |||||
0.0 grams | 100 % | |||||
0.0 grams | 100 % | |||||
0.0 grams | 100 % | |||||
147.6 grams | 90.6 % | |||||
279.4 grams | 82.2 % | |||||
534.4 grams | 66 % | |||||
684.2 grams | 56.5 % | |||||
927.6 grams | 41 % | |||||
1097.8 grams | 30.2 % | |||||
1216.4 grams | 22.6 % | |||||
1311.8 grams | 16.5 % | |||||
1382.4 grams | 12 % | |||||
1428.5 grams | 9.1 % |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/28/2020 ✔