Summary for Test 2020-07-24-45-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 212618 DEA: 044G0564 EFIS: 0417000154 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-680-M2.4/M12.4 |
| Award Date | 11/16/2017 |
| Closeout Date | 12/08/2022 |
| Work Description | ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS |
| Location Description | FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/16/2017) |
Sample Information
| Sample Taken Date | 07/24/2020 | Sample Unique Key | 45 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/24/2020 | Sample type | Verification |
| A brief description of the sample | Sample is taken from Hanson Sunol Plant | The quantity of what the sample constitutes | 1 bag |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Dennis |
| Last name of sampler or witnessed by | Yeung | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Hanson Sunol Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Hunson Sunol Plant |
|---|---|---|---|
| Aggregate Size | Aggregate Source | ||
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-07-24-45
DIME Test ID: 2020-07-24-45-1
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2020-08-24
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Reza Dineli
Date of test: 08/18/2020
Method Performed: no data
Mass of container filled with water: 7358 grams
Mass of oven-dry sample in air for Sample 1: 1571 grams
Mass of container filled with the sample and water for Sample 1: 8309 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.533
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/24/2020 ✔