Summary for Test 2020-07-31-14-6

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 214901
DEA: 044Q3304
EFIS: 0419000378
DIST-CO-RTE-PM04-CC-24-R0.4/1.0
Award Date06/12/2020
Closeout Date04/12/2021
Work DescriptionCOLD PLANE PAVEMENT AND OVERLAY WITH RUBBERIZED HOT MIX ASPHALT.
Location DescriptionCONTRA COSTA COUNTY FROM FISH RANCH ROAD TO 0.2 MILE WEST OF GATEWAY BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date07/31/2020 Sample Unique Key14
Date that the sample was received by the laboratory/organization performing the testing12/31/2019 Sample typeVerification
A brief description of the sampleMix Aggregates to use in 1/2" RHMA-O-WMA The quantity of what the sample constitutes18 Bags (Shipped in 3 group of 6)
From where was the sample collectedFabricator First name of sampler or witnessed byLisa
Last name of sampler or witnessed byNordine Title of samplerQC Lab Tech
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameDSG Sunol Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0007
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSample collected from DSG Sonul
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-31-14
DIME Test ID: 2020-07-31-14-6
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2020-08-19

Test Results


Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Reza Dineli
Date of test: 08/06/2020
Percentage of fractured, coarse, 2 faced particles tested: 96 %
Percentage of fractured, coarse, 1 faced particles tested: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/19/2020 ✔