Summary for Test 2020-08-10-29-4
Test performed: CTM 301-March 2000Project Information
| Project Identifiers | Project ID: 212630 DEA: 022H6304 EFIS: 0216000156 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-36-26.6/27.6 |
| Award Date | 06/19/2020 |
| Closeout Date | 01/05/2021 |
| Work Description | DIAMOND STAR CURVE |
| Location Description | TEHAMA COUNTY ABOUT 14 MILES WEST OF RED BLUFF FROM 0.3 MILE WEST OF BASLER ROAD TO 0.1 MILE EAST OF DIAMOND STAR ROAD |
| QA Service Level | 1 (Verified on 08/10/2017) |
Sample Information
| Sample Taken Date | 08/10/2020 | Sample Unique Key | 29 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/10/2020 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" Class II AB |
| The quantity of what the sample constitutes | not provided | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dave | Last name of sampler or witnessed by | Lockett |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D78563 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Northstate Asphalt | Transportation Laboratory (TL) Number | 002343 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Tullis - Northstate Asphalt |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Windrow | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-08-10-29
DIME Test ID: 2020-08-10-29-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2020-08-19
Test Results
How will the R value be determined?: By stabilometer
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 08/14/2020
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 99 %
As Received Gradation, Percent Passing 1/2 in. sieve: 89 %
As Received Gradation, Percent Passing 3/8 in. sieve: 78 %
As Received Gradation, Percent Passing #4 sieve: 52 %
As Received Gradation, Percent Passing #8 sieve: 32 %
As Received Gradation, Percent Passing #16 sieve: 19 %
As Received Gradation, Percent Passing #30 sieve: 10 %
As Received Gradation, Percent Passing #50 sieve: 5 %
As Received Gradation, Percent Passing #100 sieve: 3 %
As Received Gradation, Percent Passing #200 sieve: 2 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 90 %
As Used Gradation, Percent Passing 3/8 in. sieve: 79 %
As Used Gradation, Percent Passing #4 sieve: 53 %
As Used Gradation, Percent Passing #8 sieve: 32 %
As Used Gradation, Percent Passing #16 sieve: 19 %
As Used Gradation, Percent Passing #30 sieve: 10 %
As Used Gradation, Percent Passing #50 sieve: 5 %
As Used Gradation, Percent Passing #100 sieve: 3 %
As Used Gradation, Percent Passing #200 sieve: 2 %
R value: 82
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/19/2020 ✔