Summary for Test 2020-07-13-25-4

Test performed: ASTM C1038-14b

Project Information

Project IdentifiersProject ID: 213811
DEA: 112T2184
EFIS: 1116000174
DIST-CO-RTE-PM11-SD-5-R38.4/R47.3
Award Date10/29/2018
Closeout Date01/03/2024
Work Description(Alternative Delivery) Construct HOV lanes, soundwalls, culvert rehab, ITS, and bike trail on I-5 . NCC I-5 Highway Improvement.
Location DescriptionIN SAN DIEGO COUNTY IN ENCINITAS AND CARLSBAD FROM SAN ELIJO LAGOON BRIDGE TO 0.3 MILE NORTH OF PALOMAR AIRPORT ROAD OVERCROSSING.
QA Service Level1 (Verified on 12/19/2018)

Sample Information

Sample Taken Date07/13/2020 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing07/13/2020 Sample typeQuality Assurance
A brief description of the sampleRapid Setting Cement The quantity of what the sample constitutes1 bag
From where was the sample collectedJob Site First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM204001
Linked DIME Sample ID The fabricator/manufacturer/facility nameC-MAX
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandCMAX
MillUnknown Type of Cementitious MaterialRapid Set Cement

Test Details

DIME Sample ID: 2020-07-13-25
DIME Test ID: 2020-07-13-25-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Test Release Date: 2020-08-17

Test Results


Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 08/17/2020
Specimen A Initial measurement at 24 hours: 0.2976 in
Specimen B Initial measurement at 24 hours: 0.2979 in
Specimen C Initial measurement at 24 hours: 0.2671 in
Specimen D Initial measurement at 24 hours: 0.263 in
Specimen A Final measurement at 14 days: 0.2977 in
Specimen B Final measurement at 14 days: 0.298 in
Specimen C Final measurement at 14 days: 0.2673 in
Specimen D Final measurement at 14 days: 0.2631 in
The average length of change of the four specimens: 0.001 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/17/2020 ✔