Summary for Test 2020-07-24-38-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 214562 DEA: 040J7104 EFIS: 0414000029 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-1.8/4.4 |
| Award Date | 03/17/2020 |
| Closeout Date | 02/29/2024 |
| Work Description | RAISE BRIDGE AND PLACE STRUCTURAL CONCRETE. |
| Location Description | SOLANO COUNTY IN VALLEJO AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 12/03/2019) |
Sample Information
| Sample Taken Date | 07/24/2020 | Sample Unique Key | 38 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/24/2020 |
| Sample type | Verification | A brief description of the sample | 1/2 inch RHMA Sample from Plant |
| The quantity of what the sample constitutes | 14 boxes | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | CTInspectorIArechiga | Last name of sampler or witnessed by | CTInspectorIArechiga |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | SYAN VALEJO | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2020-07-24-38
DIME Test ID: 2020-07-24-38-1
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2020-08-17
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Reza Dineli
Date of test: 08/13/2020
Method Performed: no data
Mass of container filled with water: 7359 grams
Mass of oven-dry sample in air for Sample 1: 1629 grams
Mass of container filled with the sample and water for Sample 1: 8292 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.342
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/17/2020 ✔