Summary for Test 2020-07-24-37-4

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 214562
DEA: 040J7104
EFIS: 0414000029
DIST-CO-RTE-PM04-SOL-80-1.8/4.4
Award Date03/17/2020
Closeout Date02/29/2024
Work DescriptionRAISE BRIDGE AND PLACE STRUCTURAL CONCRETE.
Location DescriptionSOLANO COUNTY IN VALLEJO AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 12/03/2019)

Sample Information

Sample Taken Date07/24/2020 Sample Unique Key37
Date that the sample was received by the laboratory/organization performing the testing07/24/2020 Sample typeVerification
A brief description of the sample1/2 inch Aggregate and Fine Aggregate The quantity of what the sample constitutes9 Bags
From where was the sample collectedFabricator First name of sampler or witnessed byCTInspectorIArechiga
Last name of sampler or witnessed byCTInspectorIArechiga Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSYAN VALLEJO
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-48-0002::LAKE HERMAN QUARRY
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBatch Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-24-37
DIME Test ID: 2020-07-24-37-4
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-08-17

Test Results


Input Type: Measured
Tester's full name: Nicholas Shelly
Date of test: 08/14/2020
Grading designation: C
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4822 grams
Mass of sample on No.12 sieve (after 500 revolutions): 4216 grams
Percent loss after 100 revolutions: 4 %
Percent loss after 500 revolutions: 16 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/17/2020 ✔