Summary for Test 2020-07-22-43-5
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 214059 DEA: 042K7504 EFIS: 0417000019 |
|---|---|
| DIST-CO-RTE-PM | 04-SCL-152-7.6/M10.2 |
| Award Date | 05/24/2019 |
| Closeout Date | 04/12/2021 |
| Work Description | ROADWAY REHAB, CURB RAMPS, SIGNALS, AND STRIPING UPGRADES. |
| Location Description | SANTA CLARA COUNTY IN GILROY FROM 0.3 MILE WEST OF SANTA TERESA BOULEVARD TO ROUTE 101 |
| QA Service Level | 1 (Verified on 06/04/2019) |
Sample Information
| Sample Taken Date | 07/22/2020 | Sample Unique Key | 43 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | Not set | Sample type | Verification |
| A brief description of the sample | 1/2" HMA | The quantity of what the sample constitutes | 22 boxes |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Purvi |
| Last name of sampler or witnessed by | Shah | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construciton Los Banos | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2020-07-22-43
DIME Test ID: 2020-07-22-43-5
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-08-14
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Reza Dineli
Date of test: 08/05/2020
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1534.0 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1417.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.14 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 7.49 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/14/2020 ✔