Summary for Test 2020-07-22-43-4
Test performed: AASHTO T324-14Project Information
| Project Identifiers | Project ID: 214059 DEA: 042K7504 EFIS: 0417000019 |
|---|---|
| DIST-CO-RTE-PM | 04-SCL-152-7.6/M10.2 |
| Award Date | 05/24/2019 |
| Closeout Date | 04/12/2021 |
| Work Description | ROADWAY REHAB, CURB RAMPS, SIGNALS, AND STRIPING UPGRADES. |
| Location Description | SANTA CLARA COUNTY IN GILROY FROM 0.3 MILE WEST OF SANTA TERESA BOULEVARD TO ROUTE 101 |
| QA Service Level | 1 (Verified on 06/04/2019) |
Sample Information
| Sample Taken Date | 07/22/2020 | Sample Unique Key | 43 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | Not set | Sample type | Verification |
| A brief description of the sample | 1/2" HMA | The quantity of what the sample constitutes | 22 boxes |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Purvi |
| Last name of sampler or witnessed by | Shah | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construciton Los Banos | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | Not set | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2020-07-22-43
DIME Test ID: 2020-07-22-43-4
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2020-08-14
Test Results
Input Type: Measured
Tester's full name: Reza Dineli
Date of test: 08/10/2020
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 20000
Specified number of passes at inflection point: no data
Type and Amount of Anti-Stripping Additive: N/A
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 122.4 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 20000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 20000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 6.76 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 4.09 mm
Stripping Inflection Point (Wheel A): 18888
Stripping Inflection Point (Wheel B): 20653
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 20000
Impression at specified number of passes average: 5 mm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/14/2020 ✔