Summary for Test 2020-08-10-9-3
Test performed: ASTM D624-00-re12Project Information
| Project Identifiers | Project ID: 212657 DEA: 024G5004 EFIS: 0214000031 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI-299-1.9-2.3 |
| Award Date | 10/01/2019 |
| Closeout Date | 11/24/2021 |
| Work Description | VIADUCT WIDENING |
| Location Description | TRINITY COUNTY NEAR SALYER FROM 0.1 MILE EAST TO 0.6 MILE EAST OF WHITE HOUSE GULCH ROAD |
| QA Service Level | 1 (Verified on 09/04/2018) |
Sample Information
| Sample Taken Date | 08/10/2020 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/10/2020 | Sample type | Quality Assurance |
| A brief description of the sample | Bearing Pad | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Brad |
| Last name of sampler or witnessed by | Streeter | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Scougal Rubber | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | 18817-4R |
|---|---|---|---|
| Material/Compound/Elastomer ID | na | Samples Representing | 7 |
| Description (size) | 2"x12"x12" | Comments | |
| Description (Number of Shims) | 4 | Type of Bearing Pad | Steel |
| Description (Thickness of Shims) | 14 gage | Manufacturer(s) | Scougal Rubber |
| Batch Number | na |
Test Details
DIME Sample ID: 2020-08-10-9
DIME Test ID: 2020-08-10-9-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2020-08-11
Test Results
Number of specimens tested: 3
Input Type: Measured
Tester's full name: spaine
Date of test: 08/11/2020
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.072
Sample 1 Tear Strength: 256
Sample 2 Median Thickness: 0.078
Sample 2 Tear Strength: 247.3
Sample 3 Median Thickness: 0.071
Sample 3 Tear Strength: 261.8
UTM: 2kip
Median of the Tear Strength Values: 256 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Sample 2
Source: Bluehill Data Point File
Test graph for Sample 3
Source: Bluehill Data Point File
Test graph for Sample 1
Test was verified on 8/11/2020 ✔