Summary for Test 2020-07-24-6-5

Test performed: ASTM C1038-14b

Project Information

Project IdentifiersProject ID: 214843
DEA: 060X6704
EFIS: 0618000229
DIST-CO-RTE-PM06-TUL-63,65,99,190,198-Var
Award Date05/14/2020
Closeout Date07/15/2021
Work DescriptionREPLACE BRIDGE DECK WITH POLYESTER CONCRETE OVERLAY & PLACE CONCRETE.
Location DescriptionTULARE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/20/2020)

Sample Information

Sample Taken Date07/24/2020 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing07/24/2020 Sample typePreliminary
A brief description of the sampleRapid Setting Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedJob Site First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM204002
Linked DIME Sample ID The fabricator/manufacturer/facility nameCTS
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandCTS
MillJuarez Type of Cementitious MaterialRapid Set Cement

Test Details

DIME Sample ID: 2020-07-24-6
DIME Test ID: 2020-07-24-6-5
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Test Release Date: 2020-08-13

Test Results


Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 08/10/2020
Specimen A Initial measurement at 24 hours: 0.3288 in
Specimen B Initial measurement at 24 hours: 0.2578 in
Specimen C Initial measurement at 24 hours: 0.3158 in
Specimen D Initial measurement at 24 hours: 0.2798 in
Specimen A Final measurement at 14 days: 0.3294 in
Specimen B Final measurement at 14 days: 0.2583 in
Specimen C Final measurement at 14 days: 0.3162 in
Specimen D Final measurement at 14 days: 0.2804 in
The average length of change of the four specimens: 0.005 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/13/2020 ✔