Summary for Test 2020-08-06-6-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214841 DEA: 034H1004 EFIS: 0318000176 |
---|---|
DIST-CO-RTE-PM | 03-SIE-49-9.2/24.7 |
Award Date | 05/29/2020 |
Closeout Date | 07/29/2022 |
Work Description | INSTALL RETAINING STRUCTURE AND RSP CONCRETE EMBANKMENT. |
Location Description | SIERRA COUNTY ON ROUTE 49 AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 03/24/2020) |
Sample Information
Sample Taken Date | 08/06/2020 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/07/2020 |
Sample type | Quality Assurance | A brief description of the sample | Lenton Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | J | Last name of sampler or witnessed by | Ross |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Nucor Erico | Transportation Laboratory (TL) Number | C695452 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Erico Lenton | Intermediate Assembler or Fabricator | |
Rebar Size | #8 | Coupler Model | Lenton A2 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | L9605 | Rebar Heat Number(s) | 3500013040 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2020-08-06-6
DIME Test ID: 2020-08-06-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-08-07
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 08/07/2020
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | No. 8/25mm | 1 | -0.0003 | 0.79 | 74620 | 94455 | Service Splice | bewing |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 8/7/2020 ✔